Owens Corning® FOAMULAR® & FOAMULAR® NGX® 400/600/1000 are high strength Extruded Polystyrene (XPS) Insulation products designed for use in engineered applications requiring additional load-bearing capability. It can also be used in tapered insulation systems.

FOAMULAR® NGX® High-Performance XPS Insulation

Owens Corning® FOAMULAR® NGX® insulation offers all the performance and ease-of-use you expect from Owens Corning® FOAMULAR® insulation with industry-leading sustainability. Learn how FOAMULAR® NGX® meets the new environmental regulations for Canada and a growing list of US states.

Specifications & Literature

Building Enclosure Solutions

Owens Corning® Enclosure Solutions offers one of the largest portfolios of commercial insulation products for walls, roofs, and below-grade foundations. Engineered with Owens Corning technical expertise and supported by Building Science, Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design.

Certifications

Energy Star

Energy Star

SCS Recycled Content - Average 20%

SCS Recycled Content - Average 20%

UL Greenguard Gold

UL Greenguard Gold

Performance Attributes

Moisture resistance icon

Moisture Resistance

Durability icon

Durability

Easy to install icon

Easy to Install

Technical Information

PROPERTY

TEST METHOD3

400

600

1000

Thermal Resistance,
R-Value (180 day) minimum,
hr•ft2•°F/Btu (RSI, °C•m2/W)





ASTM C518

   

@ 75°F (24°C) mean temperature

5.0 (0.88)

5.0 (0.88)

5.0 (0.88)

@ 40°F (4.4°C) mean temperature

5.4 (0.95)

5.4 (0.95)

5.4 (0.95)

@ 25°F (-3.9°C) mean temperature

5.6 (0.99)

5.6 (0.99)

5.6 (0.99)

Long Term Thermal Resistance,
LTTR-Value4, minimum
hr•ft2•°F/Btu (RSI, °C•m2/W)



CAN/ULC S770-03

   

@ 75°F (24°C) mean temperature

5.0 (0.88)

5.0 (0.88)

5.0 (0.88)

Compressive Strength5, minimum psi (kPa)

ASTM D162140 (276)60 (414)100 (689)

Flexural Strength6, minimum psi (kPa)

ASTM C20390 (621)120 (828)150 (1035)

Water Absorption7,
maximum % by volume


ASTM C272


0.3


0.3


0.3

Water Vapor Permeance8,
maximum perm (ng/Pa•s•m2)


ASTM E96


1.1 (63)


1.1 (63)


1.1 (63)

Dimensional Stability,
maximum % linear change


ASTM D2126


2.0


2.0


2.0

Flame Spread9,10

ASTM E84101010

Smoke Developed9,10

ASTM E84175175175

Oxygen Index9, minimum % by volume

ASTM D2863242424
Service Temperature, maximum °F (°C)165 (74)165 (74)165 (74)

Linear Coefficient of Thermal Expansion,
in/in/°F (m/m/°C)


ASTM E228


3.5 x 10-5 (6.3 x 10-5)

2. Properties shown are representative values for 1" thick material, unless otherwise specified. Extruded Polystyrene Insulation may exhibit different physical properties based upon thickness. Certain physical properties are listed by minimum and maximum values per ASTM C578. For details on specific test methods, please contact Owens Corning at 1-800-GET-PINK.

3. Modified as required to meet ASTM C578.

4. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the marked R-value. Follow the manufacturer’s instructions carefully. If a manufacturer’s fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR® XPS Insulation is provided from testing at two mean temperatures, 40°F and 75°F, and from two aging (conditioning) techniques, 180 day real-time aged (as mandated by ASTM C578) and a method of accelerated aging sometimes called “Long Term Thermal Resistance” (LTTR) per CAN/ULC S770-03. The R-value at 180 day real-time age and 75°F mean temperature is commonly used to compare products and is the value printed on the product.

5. Values at yield or 10% deflection, whichever occurs first.

6. Properties shown are representative values for 2" thick material, unless otherwise specified. Value at yield or 5%, whichever occurs first.

7. Data ranges from 0.00 to value shown due to the level of precision of the test method.

8. Water vapor permeance decreases as thickness increases.

9. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions.

10. Data from Underwriters Laboratories Inc.® classified. See Classification Certificate U-197.

Applications

  • Basements
  • Floors
  • Foundations
  • Foundations > Slab
  • Foundations > Wall
  • Roofs