Skip to main content

Owens Corning® Fiberglas™ UtiliCore® insulation offers two unique solutions.

Fiberglas™ UtiliCore® HP5 Mat insulation is a needled blanket with no binder. and our Fiberglas™ UtiliCore® L-Series insulation products are low-binder blankets. Both solutions are pliable, lightweight, and offer outstanding thermal performance, making these products excellent core insulation for removable and reusable industrial pipe covers and other industrial pads and blankets.

Technical Information

PHYSICAL PROPERTIES

PROPERTY

TEST METHOD

VALUE

Operating Temperature Range

ASTM C411

L Series: up to 1000В°F (538В°C)

HP5 II Mat: up to 1100В°F (593В°C)

Corrosion Resistance

ASTM C665

Meets requirement

Fungi Resistance

ASTM C1338

Meets requirements

Odor

ASTM C1304

No objectionable odor

Moisture Sorption

ASTM C1104

< 3% by weight

Composite Surface Burning Characteristics Flame Spread

Smoke Developed 4

ASTM E84, UL 723, and CAN/ULC-S102

< 25

< 50

STANDARDS CODES COMPLIANCE

  • ASTM C553, Mineral Fiber Blanket Thermal Insulation, Type V - All UtiliCore® products
  • ASTM C1139 Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications
  • ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel 5
  • Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation 5
  • MIL-I-22023D Insulation Felt, Thermal and Sound Absorbing Felt, Fibrous Glass, Flexible. See MIL-I-22023D Compliance and Variances
  • MIL-DTL-I-24244D (Ships) Insulation Material with Special Corrosion, Chloride, and Fluoride Requirements; Type XVI 5
  • U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
  • NOTE: All UtiliCore® products comply to the Noncombustible requirements of IMO FTP Code
  • ASTM E136, Behavior of Materials in a Vertical Tube Furnace at 750°C (Noncombustible rating)
  • Doesn’t contain the fire retardant decabrominated diphenyl ether (decaBDE)
1. Limited to single layer application.

2. The surface burning characteristics of these products have been determined in accordance with ASTM E84. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.

3. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.

4. The surface burning characteristics of these products have been determined in accordance with ASTM E84, UL 723, and CAN/ULC-S102. These standards should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment, which takes into account all of the factors, which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.

5. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.

Applications

Related Products

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.