Skip to main content

Steel Stud Wall Laminate Panels (HDL / HPL)

Mineral Wool CI with Fluid or Sheet AWB

Overview

This Enclosure Solutions Wall System includes a steel stud structure with HDL/HPL panels, exterior gypsum sheathing, mineral wool continuous insulation & mineral wool cavity batt insulation. Complies with NFPA 285 (fire), ASTM E2357 (air), & ASTM E331 (water).

Get all the construction documentation you'll need, in a single click:

STEEL STUD WALL Laminate Panels (HDL / HPL) Mineral Wool CI with Fluid or Sheet AWB

Products In This Solution


Additional Products

Sold Separately

  • Interior Gypsum Board
  • Galvanized Steel Studs
  • Exterior Gypsum Sheathing
  • Air & Water Barrier (AWB)
  • Air & Water Sealing Fasteners
  • Cladding Attachment System
  • HDL / HPL Panel System

Performance Attributes

Durability

Durability

Fire Resistance

Fire Resistance

Sound Reduction

Sound Reduction

Thermal Comfort

Thermal Comfort

ASHRAE 90.1

ASHRAE Standard 90.1 requires Continuous Insulation (CI) be used for all commercial and some residential buildings in the United States. Continuous insulation is defined in 90.1 as “insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope”.

ASHRAE 90.1

ASTM E2307

ASTM E2307 measures the ability of perimeter fire barrier systems to maintain a seal and prevent interior fire spread as the exterior wall assembly deflects and deforms during fire exposure. The ASTM E2307 test exposes the joint to fire from the room of fire origin and the exterior wall to fire from both the interior and the exterior as the fire plume exits the room of fire origin through a window opening. ASTM E 2307 determines the period of time that the perimeter fire containment system will limit flame penetration through the opening between the exterior wall assembly and the floor assembly.

 ASTM E2307

Additional Attributes and Compliance

This wall assembly enclosure also meets the following codes and standards. Click a standard to learn more

Case Studies & Projects

Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design. Take a look at a few key case studies below.

Toledo, OH

Toledo, OH

Owens Corning® Thermafiber® RainBarrier® 45 mineral wool insulation was used in the construction of the ProMedica Heal and Wellness Center to minimize the loss of hot and cold and maximize energy efficiency, thermal insulation, fire protection and accoustical control.

Bothell, WA

Bothell, WA

Owens Corning® Thermafiber® RainBarrier® 45 continuous insulation was specified in the wall assembly to deliver thermal protection and moisture resistance properties that help control the infiltration of rain and moisture that can lead to rot and mold.

Contact Us

Even though we’re a global company, we’re always ready to answer your technical support questions regarding our products and solutions. Email to speak with our GETTECH team.