FOAMULAR® NGX® LT30 and LT40 extruded polystyrene (XPS) insulation is suitable for cold storage floors. Durable FOAMULAR® XPS performs well under cold storage concrete floor slabs. FOAMULAR® XPS insulation’s resistance to water absorption and water vapor transmission.
FOAMULAR® NGX® LT30/LT40
Extruded Polystyrene (XPS) Rigid Foam InsulationFOAMULAR® NGX® High-Performance XPS Insulation
Owens Corning® FOAMULAR® NGX® insulation offers all the performance and ease-of-use you expect from Owens Corning® FOAMULAR® insulation with industry-leading sustainability. Learn how FOAMULAR® NGX® meets the new environmental regulations for Canada and a growing list of US states.
Specifications and Literature
Specifications and Literature
Performance Attributes
Moisture Management
Easy to Install
Durability
Technical Information
Physical Properties
Property | Test Method | LT30 | LT40 |
Thermal Resistance3, R-Value (180 day) minimum, hr•ft2•°F/Btu (RSI, °C•m2/W) | ASTM C518 | 10.0 (1.76) | |
@ 40°F (4.4°C) mean temperature | 10.8 | ||
@ 25°F (-3.9°C) mean temperature | 11.2 (1.97) | ||
Compressive Strength6, minimum psi (kPa) | ASTM D1621 | 30 (207) | 40 (276) |
Flexural Strength7, minimum psi (kPa) | ASTM C203 | 75 (517) | 115 (793) |
Water Absorption8, maximum % by volume | ASTM C272 | 0.10 | 0.10 |
Water Vapor Permeance9, maximum perm (ng/Pa•s•m2 | ASTM E96 | 1.5 (86) | 1.1 (63) |
Dimensional Stability, maximum % linear change | ASTM D2126 | 2.0 | |
Flame Spread10, 11 | ASTM E84 | 5 | 5 |
Smoke Developed10, 11, 12 | ASTM E84 | 10 | |
Oxygen Index10, minimum % by volume | ASTM D2863 | 24 | |
Service Temperature, maximum °F (°C) | — | 165 (74) | 165 (74) |
Linear Coefficient of Thermal Expansion, in/in/ºF (m/m/°C) | ASTM E228 | 3.5 x 10-5 (6.3 x 10-5) | 3.5 x 10-5 (6.3 x 10-5) |