Owens Corning QuietR Spiral Duct Liner fits your specific duct size, compression at grooves and joints is kept to a minimum, providing consistent thermal performance throughout the entire duct system.

Performance Attributes

Acoustic Properties icon

Acoustic Properties

Thermal Comfort icon

Thermal Comfort

Durability icon

Durability

Technical Information

PROPERTY

TEST METHOD

VALUE

Maximum Temperature Limits
Internal
External

UL 181


250°F (121°C)
150°F (66°C)

Maximum Air Velocity UL 181 Erosion Test 6,000 fpm (30.5 m/s)
Water Vapor Sorption ASTM C1104

<3% by weight at 120°F (49°C), 95% R.H.

Mold Growth UL 181 Meets Requirements
Mold Growth ASTM C1338 Meets Requirements
Fungi Resistance ASTM G21 Meets Requirements
Bacteria Resistance ASTM G22 Meets Requirements

Surface Burning Characteristics
Flame Spread
Smoke Developed

UL 7231


<25
<50

  1. The surface burning characteristics of these products have been determined in accordance with UL 723. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. ASTM E84, UL 723, and NFPA 255 are considered by most officials to be synonymous surface burning test methods.