FOAMULAR® Insulating Sheathing (IS) XPS Insulation is used as sheathing over all exterior walls in wood or metal framing construction to create an effective insulating envelope over the entire structure.

FOAMULAR® NGX® High-Performance XPS Insulation

Owens Corning® FOAMULAR® NGX® insulation offers all the performance and ease-of-use you expect from Owens Corning® FOAMULAR® insulation with industry-leading sustainability. Learn how FOAMULAR® NGX® meets the new environmental regulations for Canada and a growing list of US states.

Performance Attributes

Moisture Resistance icon

Moisture Resistance

Durability icon

Durability

Easy Installation icon

Easy Installation

Technical Information

Property1

Test Method2

Value

Thermal Resistance3, R-Value (180 day) minimum,
hr·ft2·°F/Btu (RSI, °C·m2/W)
@ 75°F (24°C) mean temperature

ASTM C518 
½" Thickness 3.0 (0.53)
¾" Thickness 4.0 (0.70)
1" Thickness 5.0 (0.88)

@ 40°F (4.4°C) mean temperature

  
½" Thickness 3.2 (0.57)
¾" Thickness 4.3 (0.76)

1" Thickness

 

5.4 (0.95)

Long Term Thermal Resistance, LTTR-Value3, minimum
hr·ft2·°F/Btu (RSI, °C·2/W)
@ 75°F (24°C) mean temperature

CAN/ULC S770-03 

½" Thickness

 

N/A

        ¾" Thickness

N/A

1" Thickness

5.0 (0.88)

Comprehensive Strength4, minimum psi (kPa)

ASTM D1621

15 (103)

Flexural Strength5, minimum psi (kPa)

ASTM C203

½" Thickness

N/A

¾" Thickness

N/A

1" Thickness

65 (448)

Water Absorption6, maximum % by volume

ASTM C272

0.10

Water Vapor Permeance7, maximum perm (ng/Pa.s.m2)

ASTM E96

0.2 (11.5)

Dimensional Stability, maximum % linear change

ASTM D2126

2.0

Flame Spread8, 9

ASTM E84

5

Smoke Developed8, 9,1 0

ASTM E84

45-175

Oxygen Index8, minimum % by volume

ASTM D2863

24

Service Temperature, maximum °F (°C)

165 (74)

Linear Coefficient of Thermal Expansion, in/in/°F (m/m°C)

ASTM E228

3.5 x 10-5 (6.3 x 10-5)

1. Properties shown are representative values for 1" thick material, unless otherwise specified.
2. Modified as required to meet ASTM C578
3. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the marked R-value. Follow the manufacturer’s instructions carefully. If a manufacturer’s fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR® XPS Insulation is provided from testing at two mean temperatures, 40ºF and 75ºF, and from two aging (conditioning) techniques, 180 day realtime aged (as mandated by ASTM C578) and a method of accelerated aging sometimes called “Long Term Thermal Resistance” (LTTR) per CAN/ULC S770-03. The R-value at 180 day real-time age and 75ºF mean temperature is commonly used to compare products and is the value printed on the product.
4. Values at yield or 10% deflection, whichever occurs first.
5. Value at yield or 5%, whichever occurs first.
6. Data ranges from 0.00 to value shown due to the level of precision of the test method.
7. Water vapor permeance decreases as thickness increases.
8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions.
9. Data from Underwriters Laboratories Inc.® classified. See Classification Certificate U-197.
10. ASTM E84 is thickness-dependent, therefore a range of values is given.