Skip to main content

FOAMGLAS® T4+ CELLULAR GLASS RIGID FOAM INSULATION

Owens Corning® FOAMGLAS® T4+ cellular glass insulation is a closed cell, high performance, rigid foam board specifically designed for building and roofing applications. It provides a unique combination of properties that offer an alternative to other types of building insulation.

Applications:

  • Concrete deck - Guide specification available for download 
  • Steel Deck - Guide specification available for download
  • Walls - Submit request to learn more
  • Interiors - Submit request to learn more
  • Below-Grade - Submit request to learn more

Specifications & Literature

Building Enclosure Solutions

Owens Corning® Enclosure Solutions offers one of the largest portfolios of commercial insulation products for walls, roofs, and below-grade foundations. Engineered with Owens Corning technical expertise and supported by Building Science, Owens Corning® Enclosure Solutions deliver buildings that perform without compromising design.

Certifications

Declare

Performance Attributes

Fire Resistance

High Compressive Strength

Moisture Resistance

Thermal Comfort

Technical Information

PROPERTY

TEST METHOD

VALUE

Composition

-

Inorganic. Soda lime glass

Density, minimum pcf (kg/m3 )

ASTM C303

5.5 (88)

Service Temperature, ºF (ºC)

-

-445 to 806 (-265 to 430)

Water Absorption, maximum vol %

ASTM C240

0.1%

Water Vapor Permeability, maximum perm-in (ng/Pa-s-m)

ASTM E96

0.005 (.007)

Mold/Mildew Resistance

ASTM C1338

Pass

Corrosion Resistance

ASTM C1617

Pass (steel, less than DI water)

Hydrostatic Resistance, minimum equivalent water height in feet (meters)

ASTM D5385/C1306

34.5 (10.5)

Coefficient of Linear Thermal Expansion, maximum in/in/ºF (mm/mm/ºC)ASTM E228

5.0 x 10-6 (9.0 x 10-6)

Dimensional Stability1 , %, maximum
   @ 158°F / 97% R.H.
   @ -40°F / ambient R.H.
   @ 200°F / ambient R.H.


ASTM D2126


1.0%
1.0%
1.0%

Compressive Strength (capped),
minimum psi (kPa)

ASTM C165
Procedure A/
ASTM C240


87 (600)

Flexural Strength, psi (kPa), minimum

ASTM C203

65.3 (450)

Modulus of Elasticity, ksi (MPa), Approximate (ν = 0.25)
   Perpendicular
   Parallel


ASTM C623


145 (1000)
164 (1131)

Combustibility1

ASTM E136Non-combustible

Surface Burning Characteristics1,5, maximum
   Flame Spread Index
   Smoke Developed Index


ASTM E84


0
0

Thermal Resistance per inch @ 75ºF (24ºC) mean temperature2 , Hr-ft2 -ºF/BTU (m2 -ºC/W)

ASTM C518/ASTM C1773.4 (0.59)
  1. Unfaced only
  2. Per ASTM D5385/C1306
  3. Properties shown are representative values for 1-inch-thick material unless otherwise specified. Cellular glass may exhibit different physical properties based upon thickness. Certain physical properties are listed by minimum and maximum values per ASTM C1902. For details on specific test methods, please contact Owens Corning at 1-800-GET-PINK.
  4. Maximum change in any dimension.
  5. These laboratory tests are not intended to describe the hazards under actual fire conditions. Verify compliance with all required applicable fire assemblies.
  6. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the market R-value. Follow the manufacturer’s instructions carefully. The U.S. FTC requires the R-value of home insulation to be measured at 75°F mean temperature. R-value claims should always be compared at the same mean temperature. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data.