Skip to main content

FOAMGLAS® S3 CELLULAR GLASS RIGID FOAM INSULATION

Owens Corning® FOAMGLAS® S3 cellular glass insulation is a closed cell, high performance, rigid foam board specifically designed for building and roofing applications. It provides a unique combination of properties that offer an alternative to other types of building insulation.

Performance Attributes

Recycled materials icon

Recycled Materials

Fire Resistance icon

Fire Resistance

Moisture Resistance icon

Moisture Resistance

Thermal Comfort icon

Thermal Comfort

Technical Information

PROPERTY

TEST METHOD

VALUE

Composition

-

Inorganic. Soda lime glass

Density, minimum pcf (kg/m3 )

ASTM C3036.9 (110)
Service Temperature, ºF (ºC)

-

-445 to 806 (-265 to 430) no load

Water Absorption, maximum vol %ASTM C2400.1%
Water Vapor Permeability, maximum perm-in (ng/Pa-s-m)ASTM E960.005 (.007)
Mold/Mildew ResistanceASTM C1338Pass
Corrosion ResistanceASTM C1617Pass (steel, less than DI water)
Hydrostatic Resistance, minimum equivalent water height in feet (meters)ASTM D5385/C130634.5 (10.5)

Coefficient of Linear Thermal Expansion, maximum in/in/ºF (mm/mm/ºC)

ASTM E228

5.0 x 106 (9.0 x 10-6)

Dimensional Stability4 , %, maximum
@ 158°F / 97% R.H.
-40°F / ambient R.H.
@ 200°F / ambient R.H.


ASTM D2126


1.0
1.0
1.0

Compressive Strength (capped), minimum psi (kPa)

ASTM C165 Procedure A/ASTM C240

130 (900)

Flexural Strength, psi (kPa), minimumASTM C20372.5 (500)

Modulus of Elasticity, ksi (MPa), Approximate (ν = 0.25)
     Perpendicular
     Parallel


ASTM C623


168 (1158)
199 (1372)

Combustibility1

ASTM E136

Non-combustible

Surface Burning Characteristics1,5, maximum
Flame Spread Index
Smoke Developed Index


ASTM E84


0
0

Thermal Resistance6 per inch @ 75ºF
(24ºC) mean temperature2 ,
Hr-ft2 -ºF/BTU (m2 -ºC/W)

ASTM C518/
ASTM C177


3.0 (0.54)

  1. Unfaced only
  2. Per ASTM D5385/C1306
  3. Properties shown are representative values for 1-inch-thick material unless otherwise specified. Cellular glass may exhibit different physical properties based upon thickness. Certain physical properties are listed by minimum and maximum values per ASTM C1902. For details on specific test methods, please contact Owens Corning at 1-800-GET-PINK.
  4. Maximum change in any dimension
  5. These laboratory tests are not intended to describe the hazards under actual fire conditions. Verify compliance with all required applicable fire assemblies.
  6. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be installed properly to get the market R-value. Follow the manufacturer’s instructions carefully. The U.S. FTC requires the R-value of home insulation to be measured at 75°F mean temperature. R-value claims should always be compared at the same mean temperature. Because rigid foam plastic insulation products are not all aged in accordance with the same standards, it is useful to publish comparison R-value data.

Applications

  • Roofs > Flat

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.