Owens Corning® Metric Fiberglas™ Pipe Insulation is molded out of heavy density resin bonded inorganic glass fibers that come in one-piece, 36" (914mm) long, hinged sections. The insulation is tailored to fit for copper, iron, and PVC pipe applications.
Metric Fiberglas™ Pipe Insulation
Specifications & Literature
Specifications & Literature
Data Sheets (1)
Brochures (2)
Safety Documents
Guide Specifications (2)
Technical Documentation (2)
Installation Instructions (3)
Case Studies (2)
Environmental Product Declarations (1)
Certifications (1)
LEED (5)
Certifications
Certifications
UL Greenguard Gold
Performance Attributes
Performance Attributes
Durability
Easy Installation
Mold and Mildew Resistance
Technical Information
Technical Information
Physical Properties
PROPERTY | TEST METHOD | VALUE |
Density (size dependent) | ASTM C302 | 3.5 to 5.5 pcf |
Operating Temperature Range 1 | ASTM C411 | 0°F to 1,000°F(-18oC to 538°C) |
Water Vapor Sorption | ASTM C1104 | Less than 5% by weight |
Corrosion | ASTM C665 | Pass - steel, copper, or aluminum |
Corrosion | ASTM C1617 | Pass - steel |
Jacket Temperature Limitation | ASTM C1136 | -20°F to 150°F (-29°C to 66°C) |
Jacket Permeance | ASTM E96, Proc. A | 0.02 perm |
Burst Strength, min | ASTM D774/D774M | 100 psi |
Composite Surface Burning Characteristics 2 | UL 723, ASTM E84 or CAN/ULC-S102 | Flame Spread 25 |
Standards Codes Compliance
- ASTM C547, Mineral Fiber Pipe Insulation, Types I, Grade A; and Type IV, Grade B
- ASTM C585, Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing
- ASTM C1136, Flexible Low Permeance Vapor Retarders for Thermal Insulation: Types I, II, III, IV
- UL Labeled for Flame Spread Index of 25 or less and Smoke Developed Index of 50 and if fully building code compliant
- UL Listed and Labeled for use over PVC and other polymer pipes UL Category BSMP
- ASTM C795, Thermal Insulation for Use in Contact with Austenitic Stainless Steel 3
- Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation3
- MIL-PRF-22344E, Insulation, Pipe, Thermal, Fibrous Glass
- MIL-DTL-32585, Type I, Form 4, Facing A
- MIL-DTL-24244D (Ships) Insulation Material with Special Corrosion, Chloride, and Fluoride Requirements3
- NFPA 90A and 90B
1. With heat-up schedule. when operating temperatures are between 850oF and 1,000oF.
2. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. Values are reported to the nearest 5 rating.
3. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance. Certification needs to be specified at time of order.
Applications
Applications
- Pipe and Equipment
- Pipe and Equipment > Equipment
- Pipe and Equipment > Equipment > Mechanical Room
- Pipe and Equipment > Process Piping
- Pipe and Equipment > Process Piping > Above Ground Piping
- Pipe and Equipment > Process Piping > Above Ground Piping > Flatwork
Related Products
Related Products
Contact Us
Contact Us
Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.