Skip to main content

Fiberglas™ Insul-Quick® Insulation

Owens Corning® Fiberglas™ Insul-Quick® Insulation is a lightweight insulation composed of glass fibers bonded together in a semi-rigid, board-like form with a special high temperature binder.

Technical Information

Physical Properties

PROPERTY

TEST METHOD

VALUE

Hot Surface Performance

ASTM C411

Up to 850°F (454°C)
Maximum thickness 6" (152 mm)
Up to 650°F (343°C)
Maximum thickness 8" (203 mm)

Compressive Strength
at 10% Deformation
at 20% Deformation

ASTM C165

90 lb/ft2 (4309 Pa)
130 lb/ft2 (6225 Pa)

Nominal Density

ASTM C303

3.0 pcf (48 kg/m3)

Water Vapor Sorption

ASTM C1104

< 2.0% by weight, at 120°F (49°C), 95% R.H.

Shot Content

ASTM C1335

Negligible

Composite Surface Burning Characteristics
Flame Spread
Smoke Developed10

UL 723, ASTM E84 or CAN/ULC-S102

25
50

Standards Codes Compliance

  • ASTM C612, Mineral Fiber Block & Board Thermal Insulation, Types IA, IB, II
  • ASTM C795, Thermal Insulation for Use Over Austenitic Stainless Steel11
  • Nuclear Regulatory Commission Guide 1.36, Non-Metallic Thermal Insulation11
  • U.S. Coast Guard Approval No. 164.109, Noncombustible Materials
  • CAN/CGSB-51.10–Type 1, Class 1

1. Includes core weight
2. All values are approximate.
3. Limited to single layer applications above 650°F (343°C), but not greater than 6" (152mm) thickness.
4. With heat up schedule.
5. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. Values are reported to the nearest 5 rating.
6. Preproduction qualification testing
7. It is critical to have the right amount of intake ventilation and to adequately seal the attic floor to prevent pulling air from conditioned space.
8. For each Gable Mount fan, Owens Corning Roofing requires 890 square inches of intake. See instructions for details.
9. For each Roof Mount fan, Owens Corning Roofing requires 600 square inches of intake. See instructions for details.
10. The surface burning characteristics of these products have been determined in accordance with UL 723, ASTM E84 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating.
11. Preproduction qualification testing complete and on file. Chemical analysis of each production lot required for total conformance.

Applications

  • Pipe and Equipment
  • Pipe and Equipment > Equipment
  • Pipe and Equipment > Equipment > Mechanical Room
  • Pipe and Equipment > Process Piping
  • Pipe and Equipment > Process Piping > Above Ground Piping
  • Pipe and Equipment > Process Piping > Above Ground Piping > Flatwork

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.