Skip to main content

PureSolution® Technology (TRS-PST & GEM®) Range Insulation

Owens Corning® Range Insulation with Pure Solution Technology products are designed for high temperature commercial and industrial applications up to 1000ºF.

Performance Attributes

Thermal Comfort icon

Thermal Comfort

Sound Absorbent icon

Sound Absorbent

Acoustic Performance icon

Acoustic Performance

Technical Information

The soft white flexible material comes in multiple thicknesses and densities providing ease of handling and installation. Owens Corning® Range Insulation with PureSolution® Technology meets thermal performance with virtually no smoke and odor at elevated temperatures making is an excellent choice for appliance range applications.


Thermal Conductivity

GEM® INSULATION WITH PURESOLUTION® TECHNOLOGY

Thickness1 (Inches)

Nominal K Value [BTU-IN/(HR • FT2 ºF)]

Nominal K. W/mK

75ºF

300ºF

500ºF

23ºC

149ºC

260ºC

0.375

0.22

0.30

0.42

0.032

0.044

0.061

0.500

0.22

0.30

0.42

0.032

0.044

0.061

0.625

0.22

0.29

0.42

0.032

0.042

0.061

0.750

0.22

0.29

0.42

0.032

0.042

0.061

1.000

0.22

0.29

0.42

0.032

0.042

0.061

1. Thickness value is nominal. Product control is on thermal conductivity

THERMORANGE® SYSTEM (TRS) WITH PURESOLUTION® TECHNOLOGY


Product Family1

Nominal K Value [CTU-IN/(HR FT2 °F)]

Nominal K. W/mK

75°F

300°F

500°F

23°C

149°C

260°C

TRS-400.220.350.520.0320.0500.075
TRS-50

0.21

0.31

0.44

0.031

0.045

0.063

TRS-60

0.21

0.30

0.42

0.031

0.044

0.060

SOUND ABSORPTION COEFFICIENT, ASTM C423 – TYPE A MOUNTING2

PURESOLUTION® TECHNOLOGY

THICKNESS (INCHES)

HZ: 125

250

500

1000

2000

4000

NRC

SAA

0.750

0.05

0.13

0.52

0.97

1.03

1.04

0.65

0.66

2. Nominal samples were measured in accordance with ASTM C423. These measured absorption coefficients are representative of the product with mean specification properties. While these values are an accurate representation of our product, they are for design approximations only. Production, testing, and application variabilities will alter results. Specific designs should be evaluated in end-use configurations.

Applications

  • Appliance and OEM

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.