Technical Information
Property | Test Method | Value | ||
---|---|---|---|---|
Thermal Resistance | ASTM C 177/C 518 | Thickness | Pre-lam. | Post-lam. |
3.4" | R-10.8 | R-10 | ||
3.7" | R-11.9 | R-11 | ||
4.3" | R-14.1 | R-13 | ||
5.3" | R-17.3 | R-16 | ||
6.3" | R-20.6 | R-19 | ||
| | 8.0" | R-27.1 | R-25 |
| | 9.25" | R-32.5 | R-30 |
Surface Burning | ASTM E 84 / UL723 | Flame spread index < 25 | ||
Combustion Characteristics | ASTM E 136 | Non-combustible | ||
Water Vapor Sorption | ASTM C 1104 / C 1104M | ≤ 0.2% by volume | ||
Fungi Resistance | ASTM C 1338 | Passes | ||
Corrosiveness | ASTM C 665, sec. 13.8 | Passes | ||
Odor Emission | ASTM C 1304 | Passes | ||
Dimensional Tolerances | ASTM C 167 | Length, - 0" / + 1/2" |