Skip to main content

Owens Corning Rotary Duct Liner absorbs noise within HVAC Equipment and contributes to indoor comfort by lowering heat loss or gain through metal casings.

Performance Attributes

Acoustic Properties icon

Acoustic Properties

Thermal Comfort icon

Thermal Comfort

Durability icon

Durability

Resources

Top 3 Reasons Why QuietR® Rotary Duct Liner is the Best Choice
Top 3 Reasons Why QuietR® Rotary Duct Liner is the Best Choice
QuietR® Rotary Duct Liner: New Packaging with Easy-Open Pull System (English)
QuietR® Rotary Duct Liner: New Packaging with Easy-Open Pull System (English)
QuietR® Duct Liner: New Packaging with Easy-Open Pull System (Spanish)
QuietR® Duct Liner: New Packaging with Easy-Open Pull System (Spanish)

Technical Information

PROPERTY

TEST METHOD

VALUE

Operating Temperature ASTM C411 250°F (121°C)
Maximum Air Velocity UL 181 Erosion Test ASTM C1071 6,000 fpm (30.5 m/sec)
Water Vapor Sorption (by weight) ASTM C1104

<3% at 120°F (49°C), 95% R.H.

Fungi Resistance ASTM C1338 Meets requirements
Fungi Resistance ASTM G21 Meets requirements
Bacteria Resistance ASTM G22 Meets requirements

Corrosiveness1

ASTM C665 (Corrosiveness Test) Will not cause corrosion greater than caused by sterile cotton on aluminum or steel*

Thermal Conductivity
k at 75°F (λ at 24°C mean)
R-2.2
R-4.2
R-6.3
R-8

ASTM C518

Btu•in/hr•ft2•°F

0.23
0.24
0.24
0.24

W/m•°C

0.034
0.035
0.035
0.035

Surface Burning Characteristics2
Flame Spread
Smoke Developed

ASTM E84, UL 723, CAN/ULC S102


25
50

  1. When wet, coated surfaces of QuietR® Rotary Duct Liner in contact with galvanized steel may cause discoloration of the sheet metal.
  2. The surface burning characteristics of these products have been determined in accordance with UL 723 or CAN/ULC-S102. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. UL 723 and ASTM E84 are the same test methods.

Applications

  • Air Distribution
  • Air Distribution > Duct Insulation

eBooks & Guides

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.