The OptiLiner Banded Liner System is designed to maximize the thermal performance of Owens Corning EcoTouch Insulation for MBI Plus with PureFiber Technology light density fiberglass insulation in metal building roof and wall applications.
Fiberglass Insulation
OptiLiner® Banded Liner System
Specifications & Literature
Specifications & Literature
Safety Documents
Guide Specifications (1)
Technical Documentation (1)
Certifications
Certifications
SCS Recycled Content - Average 65%
UL Greenguard Gold
Performance Attributes
Performance Attributes
Acoustic Properties
Thermal Comfort
Moisture Management
Technical Information
Technical Information
Property | Test Method | Value |
---|---|---|
Insulation
| ||
Noncombustibility
| ASTM E136
| Noncombustible |
Water Vapor Sorption
| ASTM C1104
| < 5% by weight |
Odor Emission
| ASTM C1304
| No objectionable odor1 |
Corrosiveness
| ASTM C665
| No corrosion greater than comparative item |
Fungi Resistance
| ASTM C1338
| No growth greater than comparative item |
FACING | ||
Facing Permeance
| ASTM E96
| ≤ 0.02 perms |
Fungi Resistance
| ASTM C1338
| No growth greater than comparative item |
- No odor for a minimum of 3 of 5 panel members.
Applications
Applications
- Roofs
- Roofs > Flat
- Roofs > Pitched / Curved
- Walls
Related Products
Related Products
Contact Us
Contact Us
Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.